“Generator Tips For Good Service”

 

  1. When starting your generator always start it and shut it down with all appliances turned off.
  2. When starting the generator, do not engage the starter more than 10 seconds at a time.  Wait 30 seconds between trying to start it again.
  3. Run the generator for two full minutes before beginning to turn on appliances and then turn them on one at a time.
  4. When traveling at high altitudes the generator can lose power due to lower-diversity air and may require reducing the number of appliances and electrical devices in use.
  5. Following the maintenance schedule in your generators operator manual is a must for proper performance.
  6. The old saying “If you use it you won’t lose it applies to generators”.

 

Generator Trouble Shooting

 

Symptoms/Problems                    Possible Cause                       Checks/Corrections

 

Genset fails to turn over                   Low Battery                               Battery fluid level low

Starter won’t engage                        Fuse blown/Bad Starter              Replace Fuse

Genset starter is slow                       Battery connection bad               Tighten battery cables

 

 

Starter turns Genset Engine               Fuel below ¼ in tank                  Add fuel to ½ full

properly, but engine won’t                Genset shutoff valve closed         Open shutoff valve

crank                                              Low oil level                              Fill oil to full mark

                                                      Spark plugs fouled                      Replace spark plugs

                                                      Defective ignition coil                  Replace coil

                                                      Carburetor varnish clogged         Replace/Rebuild

                                                      Air filter clogged             Replace filter

 

 

Genset starts but stops                     Low oil levels                             Fill oil to full mark

when start switch is                          Bad voltage regulator                 Replace regulator

released

 

 

Genset runs but                               Bad voltage regulator                 Replace regulator

produces no power                           Bad Starter                                Replace starter

                                                      Loss of polarity                          Magnetize armature